Software HTC - Shell and Tube

The new shell and tube Onda HTC-SHELL 3.70.0 software is online !

You will find the new HDE, SPE and OVS !


New Brazed Plate Heat Exchanger S727

New S727 dual circuit evaporator

The new Onda Brazed Plate S727 is the larger plate in the BHE portfolio and it has been developed to respond to Air Conditioning and

Process Cooling applications with low pressure refrigerants as R1234ze, R515B, R513A and R134a.

The design of the plate corrugation pattern has been optimized thanks to a CFD analysis supported by thermal laboratory test.

New patented distribution system which allows to achieve stable performance with large plate package reaching a cooling capacity up to 700 kW .

Download the leaflet !


AHR EXPO 2022

Onda will be at AHR EXPO 2022 in Las Vegas from January 31 to February 2.
Come see us at booth C4744, Central Hall !


New Brazed and Air Software 2021

img

 

The new release of the selection software for the air products “UNIT SELECTOR HTU 211001” is now available on our website!

You will find the new V-shape range of dry coolers and condensers “FVD-CVD” and many other new features.

Download it now!

https://www.onda-it.com/eng/download/


Onda SpA Laboratory

Onda S.p.A. has a modern and efficient laboratory, equipped for the execution of accurate thermal tests, and can claim important collaborations with research societies, professionists and universities.

All the products are optimized thanks to CFD analysis and supported by thermal laboratory tests

 


New Air and Brazed software 2021

img

The new ONDA Brazed Plate Heat Exchanger HTC-BPLATE 3.6.0 and AIR  UNIT SELECTOR 210427 software  are  available  with new BPHE models and refrigerants !

Go to the download area to find it !


Al testo

Plate Heat Exchangers Working Principle

PLATE HEAT EXCHANGER WORKING PRINCIPLE

PLATE  HEAT  EXCHANGERS

Heat Exchangers

Plate Heat Exchangers were first produced in the 1920s and have since been widely used in a great number of sectors.

A plate exchanger consists of a series of parallel plates that are placed one above the other so as to allow the formation of a series of channels for fluids to flow between them.

The space between two adjacent plates forms the channel in which the fluid flows.

Inlet and outlet holes at the corners of the plates allow hot and cold fluids through alternating channels in the exchanger so that a plate is always in contact on one side with the hot fluid and the other with the cold.

The size of a plate can range from a few square centimeters (100 mm x 300 mm side) up to 2 or 3 square meters (1000 mm x 2500 mm side). The number of plates in a single exchanger ranges from just ten to several hundred, so reaching surface exchange areas up to thousands of square meters.

The figure shows the flow of fluids inside the exchanger. Fluids are divided into several parallel streams and can produce a perfect countercurrent.

Generally, these plates are corrugated in order to increase the turbulence, the thermal exchange surface and to provide mechanical rigidity to the exchanger. Corrugation is achieved by cold forging of sheet metal with thicknesses of 0.3mm to 1 mm.

The most frequently used materials for the plates are stainless steel (AISI 304, 316), titanium and aluminium.

The corrugation on the plates forces the fluid on a tortuous path, setting a space between two adjacent plates b, from 1 to 5 millimeters.

The fluids can cross the channels in series (a less common solution) or in parallel by making counter-current or current configurations.

The serial configuration is used when there is a small flow rate for each fluid but high heat jump; the greatest problem is with a high pressure drop and an imperfect counter-current.

The parallel configuration with countercurrent channels is used for high flow rates with moderate temperature drops, and is the most widely used.

When there is a great difference between the flow rates (or between the maximum permissible pressure drop) of the two fluids, the exchanger can run twice by the fluid with a lower flow (or higher losses) to balance the values of pressure drops or specific flow rates in the channels.

The figure shows the different configurations: in parallel, in series and mixed

One of the most common problems for plate heat exchangers is an irregular supply of the all channels in parallel. In fact, the fluid tends to distribute in greater quantities in the first channels rather than the last ones in order to balance the pressure drop.

As the number of plates increases, even distribution declines, resulting in a decrease in the overall performance of the exchanger.
There are two basic types of plate heat exchangers: BPHE-Brazed Plate Heat Exchangers and PHE-Plate Heat Exchangers.

Plate and Frame Heat Exchangers

 

In the PHE the plates create a frame where the plates are pressed with headers and tie bars, and the seal is guaranteed by gaskets. Gaskets, in addition to their sealing effect, serve to direct the flow of the fluids, and are placed along the grooves at the edges of the plates.

The maximum temperatures used for sealing heat exchangers are between 80°C and 200°C while pressures can reach 25 bar.
Gaskets are available in various types of butyl or silicone rubber.

The main characteristics of these types of heat exchangers are:
- quick and easy dismantling for cleaning and control operations
- adaptation to variable operating conditions by adding or removing heat plates to modify the installed thermal flow
- any fluid leaks due to non-perfect sealing of the gaskets do not contaminate the other fluid but are directed away
- materials that are poorly adapted to soldering, such as titanium, may be used
- the gaskets limit the maximum pressure and temperature values
- potentially high costs due to the design of moulds, presses and all the production process
- high cost of the gaskets

Brazed Plate Heat Exchangers

Brazed plate heat exchangers have no headers, tie bars or sealing gaskets because the plates are furnace brazed at temperatures of 1100°C.

During the assembly phase, a sheet of brazing material (generally copper but also nickel) is placed between the plates, the pack is pressed and subsequently baked for some hours.

The BPHE exchanger is more compact, lighter and less bulky than one with gaskets.
The image shows the path made by the hot and cold fluid.

The brazing material carries out the function both of the gaskets and the frame.

These exchangers are generally used with chevron corrugated plates, which are assembled alternating the corrugation directions in order to create a lattice contact.

The crossing points between the corrugations of two coupled plates form a dense network of contact points that confer pressure tightness and induce swirling streams that improve heat exchange.

In this way, the turbulence of the fluids is high even at low nominal input speeds and the flow passes from laminar to turbulent for low flow rates.

The figure shows a cross section of an exchanger with 8 plates in total (6 of which are useful for heat exchange) in which the 3 channels used for the passage of the refrigerant fluid (in light blue) and the 4 for water (in red) are seen.

It is immediately noticeable that the path made by the fluids is chaotic, in fact, the cross section varies continuously.

The main disadvantage of these exchangers is that they are not removable and so maintenance and cleaning are not possible or at least difficult, and no flexibility exists as the number of plates can in no way be varied.

The surface of the plates is corrugated in order to increase the turbulence of the fluid during the flow into the channels.

The figure highlights the main geometrical parameters of the corrugation:

Corrugation pitch p; corrugation height b and chevron angle β compared to the main direction of the flow.

The inclination of the plate corrugations has a determining effect on thermal exchange and load losses. In fact, a pair of plates with a high β angle (> 45 °) gives a turbulence and therefore a high heat exchange with a higher pressure drop.

A smaller angle (β <45 °) causes a lower turbulence flow and lower heat exchange coefficients but also lower pressure drops.

The search for a compromising β angle between high exchange coefficients and acceptable load losses is therefore essential.

The corrugation height b has an important effect on the exchange coefficients because a greater depth causes greater turbulence.

These two picture below show an Onda case study of the flow inside the channel of a braze plate heat exchanger, you can see the flow going inside the channel in and out of the BPHE

 

The height and pitch of the corrugations increase the plate exchange surface area: the surface enlargement factor φ is defined as:

Φ = actual corrugated surface area / projection area corrugated surface

Brazed-Plate-CFD-Flux

The actual area is difficult to compute, so in order to compare different exchangers, reference is made to the projected area.

It should be kept in mind that heat exchangers with the same projected area (ie plates of the same size) may have different effective areas depending on the value of the surface enlargement factor φ.

The ratio between the plate length and the plate width W also affects performance but to a lesser degree than other variables. In general, a high ratio between plate length and width gives high exchange rates but higher load losses.

Enrico Golin, R&D Onda S.p.A.

 


2020 Purdue Conferences

Onda attended the “2020ne Purdue Conferences (Compressor Engineering – Refrigeration and Air Conditioning – High Performance Buildings)”, May 24-28, 2021, presenting the original paper “R1234ze(E) As Drop-In Replacement For R134a In A Micro-Fin Shell-And-Tube Evaporator: Experimental Tests And Calculation Model”.

With this active contribution to the worldwide research against global warming, Onda consolidates its presence in the international scientific network.

The complete presentation can be found at the link https://youtu.be/NuHCRUiaFq0

 


New Gasketed Plate Heat Exchangers GG004

img

Plate and Frame model GG004

Onda present the new model of gasketed plate heat exchanger, the GG004.

It have a DN50 - 2" AISI 316 connections and it can reach PN16 Bar.

The exchange plate are available in AISI316 - AISI304 - Titanium and the gasket in NBR - EPDM - VITON - HNBR.


New Brazed Plate Heat Exchangers S87 e S93

 

img

Onda is introducing the new BPHE models S87 and S93 for HVAC&R applications with boosting performance +30% vs current S82 in terms of kW/m2.

The design of the plate corrugations pattern has been optimized thanks to a CFD analysis supported by thermal laboratory test.

The new Onda brazed plates S93 and S87 have been developed to respond to high efficiency and low water pressure drop market demand using high pressure refrigerants as R454B, R32 and R410A
New patented distribution system which allows to achieve stable performance with large plate package.

BENEFITS VS S82
• Evaporator and condenser average performance: +30% kW/m2
• Lower DPwater -25% at same flow rate
• Stainless steel average weight saving : -20%

CONFIGURATION
• Capacity range 20 – 90 kW
• Two model range PS 30 barg, PS 49 barg